Power specification - AC input
-
Environmental
-
Input voltage
3Φ 380 ÷ 415 Vac
Operating temperature
-30°C ÷ +50 °C
AC input connection
3P+N+PE (Wye configuration), TN/TT
Humidity
5% ÷ 95% RH, Non-Condensing
Max input current
3Φ 86A
Altitude
≤ 2.000 m
Frequency
50 Hz / 60 Hz
IP degree
IP55
Power factor
> 0.99
Mechanical resistance
IK10 (not including screen & RFID module)
Efficiency
>94%
Cooling method
Fan cooling
Power specification - DC output
-
Mechanical
-
Output voltage range
CCS2: 150 ÷ 950 Vdc
Dimension
700 mm x 330 mm x 1.800 mm
Max output current
CCS2: 120A
Weight
235 kg
Maximum output power
60 kW
Cable length
4 m
Voltage/Current accuracy
±2%
Protection
-
User interface & control
-
Input protection
OVP, OCP, OPP, OTP, UVP, RCD, SPD
Display
7'' LCD
Output protection
SCP, OCP, OVP, LVP, OTP, IMD
Push buttons
Operation Buttons / Emergency Stop Button
Regulation
-
User Authentication
OCPP 1.6 JSON, QR Code, App
Accessibility
-
Meter
AC MID Meter, Integrated DC Meter
Safety
CE, CB
Communication
-
Certificate
IEC 61851-1, IEC 61851-23, IEC 61851-21-2
External
Ethernet, Wi-Fi and 4G
Charging interface
DIN 70121, ISO 15118-2
Internal
CAN bus / RS485
National
UK Public CP Regulation 2023 (manufacturer requirements)
Contactless Solution
-
-
-
Payment terminal
Yes, Payter P66
Ware Number
85044060