MSXE 1250 - MCCB WITH ELECTRONIC RELEASE - INTERLOCKED - LSIG - FRONT TERMINALS - 50kA 4P 1250A 690V

Code: GWD9417B
Range: MSX
Moulded case circuit breaker for power distribution
The moulded case circuit breakers MSX range is made up of circuit breakers with thermo-magnetic release, circuit breakers with thermo-magnetic release and Overcurrent Protection, circuit breakers with electronic release and switch disconnectors.

Technical Info

Information
Download
Software
Certificates
Description Interruttore automatico scatolato
Code MSXE 1250
No. of poles 4P
Rated current 1250 A
Release Electronic
 ELECTRICAL CHARACTERISTICS -
MECHANICAL CHARACTERISTICS -
Standard IEC/EN 60947-2
Execution Fixed
Use category B
DIN rail mounting No
Rated frequency (Hz) 50 / 60
Can be equipped with motor operator Yes
Rated operating voltage (Ue) 690 Vac
Compatible interlock Cable (mechanism supplied)
Rated impulse withstand voltage (Uimp) 8 kV
Terminals supplied Front FB Extended
Overvoltage category IV
Assembly position Any
Insulation voltage (Ui) 800 V
Upline/downline power supply Yes
Thermal regulation 0,4 - 0,5 - 0,63 - 0,8 - 0,9 - 0,95 - 1 x In
Electrical life (415Vac) 4.000 cycles
Magnetic regulation
Electronic LSIG
Mechanical life 5.000 cycles
Neutral protection 50% - 100% x Ir
Operating temperature -5°C +65°C
Total power loss 281.24 W
Stocking temperature -20° +65°
Rated short-circuit current making capacity (Icm) -
Weight (kg) 25
Rated short-time withstand current for 0,3s (Icw) 15 kA
Width 280 mm
Idn regulation -
Height 370 mm
DT regulation -
Depth 120 mm
SERVICE BREAKING CAPACITY (ICU) -
 RATED BREAKING CAPACITIY (ICS)  -
220/240Vac 85 kA
220/240Vac 65 kA
400/415Vac 50 kA
400/415Vac 38 kA
440Vac 45 kA
440Vac 34 kA
525Vac 30 kA
525Vac 23 kA
690Vac 20 kA
690Vac 15 kA
250Vdc -
250Vdc -
Ware Number 85362010

Product Data Sheet

Information and general recommendations

User guide

User guide

Technical characteristics - IT

Technical characteristics - EN

Brochure - EN

Brochure - IT

Technical characteristics - ES

PRICE

Estimation of electrical systems

Show more

PBT-Q

Low voltage systems and boards

Show more

CADpro

Advanced design of electrical systems

Show more

PROJEX

Low voltage system design

Show more

AUTOCAD Plugin

Plugin with GEWISS products for the software AUTOCAD®

Show more

CE marking

EQUIPMENT AND NOTES
NOTES: tthe codes with the final letter B indicate circuit breaker with cable mechanical interlock already fitted on it (cable for mechanical interlock to be ordered separately).
ACCESSORIES SUPPLIED: operating lever extension for manual closing and opening operations.
CHARACTERISTICS: current regulation field Ir = 0.4 ÷ 1 x In.
Neutral 100% or 50% protected for 4P circuit breaker.
services

Do you need technical assistance?

Contact us to get the answers to your questions: plant, regulatory or product questions.

Find Gewiss

Are you looking for an installer or a sales point?

Find your trusted dealer or installer.

Write to us

Do you need information on Gewiss products or services?