Code: GW96331
Range: 90 AM Range
Modular accessories
The 90 AM range, in addition to auxiliaries common for the all circuit breakers, comprises many modular accessories for the protection, command, programming, measurement and signalling in electrical systems.

IP20

Technical Info

Information
Download
Software
Certificates
Description Residual current relay with separate toroid
Type A
Dimensions 3 modules
Standard EN 60947-2 Annex M
Tightening torque 0,5 Nm
Rated operating voltage (Ue) 230 V (± 10%)
Red LED report Exceeding the threshold IΔn after the delay time Δt
Resistance at test voltage 2kV at 50Hz for 1 minute (1kV per measurement circuit)
Green LED report Device properly powered
Rated frequency (Hz) 40/60 Hz
Local reset Yes
Regulation of IΔn 0,03 - 0,1 - 0,3 - 0,5 - 1 - 1,5 - 2 - 3 - 5 - 10 - 20 - 30 A
Local test Yes
Regulation of delay time Δt 0 - 0,25 - 0,5 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 10 s
Output contact type 1 changeover (10 A - 250 V - AC1)
Insulation class II
IP degree IP20
Self-consumption 1,5 W
Working temperature -10°C +55°C
Maximum cable section (ridig/flexible) 6 mm²
Stocking temperature -20°C +70°C
Ware Number 85364900

Product Data Sheet

Technical characteristics - IT

Technical characteristics - DE

Technical characteristics - EN

Technical characteristics - ES

User guide

CENTRAL

Quotation and Thermal test of modular enclosures

Show more

PROJEX

Low voltage system design

Show more

PBT-Q

Low voltage systems and boards

Show more

CADpro

Advanced design of electrical systems

Show more

PRICE

Estimation of electrical systems

Show more

ENERGYpro

Boards for building sites, campings-piers and distribution

Show more

Reach Declaration

Conformity declaration

CE marking

EQUIPMENT AND NOTES
CHARACTERISTICS: the tripping (Idn) and delay (dt) thresholds are adjustable:
Idn (A): 0.03 - 0.05 - 0.1 - 0.25 - 0.3 - 0.35 - 0.5 - 1 - 1.5 - 2 - 3.
dt (s): 0 - 0.25 - 0.5 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 10.
NOTE: mounting on DIN rail EN 50022. For the operation of the residual current protection, it is necessary to use: the residual current relay, a suitable toroid, and a release for the associated circuit breaker.
services

Do you need technical assistance?

Contact us to get the answers to your questions: plant, regulatory or product questions.

Find Gewiss

Are you looking for an installer or a sales point?

Find your trusted dealer or installer.

Write to us

Do you need information on Gewiss products or services?