en
it

RESTART WITH AUTOTEST PRO - COUPLED WITH RCCB'S - 2 POLES - 40 A TYPE A[IR] Idn=0,3 A 230 V ac - 5 MODULES EN 50022

Code: GW90918
Range: 90 ReStart Range
Automatic reclosing devices
In the event the switch trips, the ReStart devices, after checking the system status, restore the power supply thereby ensuring maximum continuity of service in complete safety.
Available for both residual current circuit breakers and residual current circuit breakers with overcurrent protection, the range is characterized by the Autotest functions, with periodic and automatic control of the residual current protection without interrupting the power supply and PRO with extended control of the system.

Technical Info

Information
Download
Software
Certificates
Description Automatic reclosing device
Code ReStart Autotest PRO 2P
Rated voltage AC 230 V
Rated frequency (Hz) 50Hz
Rated current 40 A
Rated residual operating current 300 mA
Type of residual current protection A [IR]
Number of poles 2P
 ELECTRICAL CHARACTERISTICS -
MECHANICAL CHARACTERISTICS -
Standard IEC EN 63024, IEC EN 61008-1, IEC EN 61008-2-1
Maximum operating frequency 30 oper./h
Distribution system TT - TN-S
Mechanical endurance 4000
Insulation voltage (Ui) 500 V
Operating temperature -25°C ÷ +60°C
Dielectric strength test voltage between pole and earth 2500 a.c. for 1 minute
Stocking temperature -40°C ÷ +70°C
Rated impulse withstand voltage (Uimp) 4 kV
No. modules 5
Overvoltage category III
Completeable
with
RS485 BUS module GW90992
Rated non-operating resistance between live parts and earth (Rdo) 2,5 kΩ
FEATURE AUXILIARY CONTACT -
Rated operating resistance between live parts and earth (Rd) 5 kΩ
Type of contacts Photomos (potential free)
AUTOTEST FUNCIONT -
Operating modes NO/NC/NC + pulse
Autotest (automatic RCCB protection test) Yes
Voltage operating 5÷230 a.c. / d.c.
RESTART FUNCTIONFUN -
Operating frequency 50 Hz
Automatic reclosure for untimely tripping Yes
Current operating 0,6 (min) - 100 cosφ=1 (max)
Earth failure test Yes
Use category AC12
Continuous system monitoring Yes
Terminal section ≤ 2,5 mm²
Ware Number 85362010

Product Data Sheet

User guide

Technical characteristics - IT

Technical characteristics - DE

Technical characteristics - EN

Technical characteristics - ES

RESTART

Automatic reclosing devices ReStart

Show more

CENTRAL

Quotation and Thermal test of modular enclosures

Show more

PROJEX

Low voltage system design

Show more

PBT-Q

Low voltage systems and boards

Show more

CADpro

Advanced design of electrical systems

Show more

PRICE

Estimation of electrical systems

Show more

Reach Declaration

Conformity declaration

Display the certificate

CE marking

EQUIPMENT AND NOTES
CHARACTERISTICS: after RCCB has tripped, ReStart checks the insulation prior to the automatic reclosure. In the event of a fault (earth leakage), ReStart will not reset the circuit breaker but will continue to monitor the circuit every 2 minutes reclosing the circuit breaker when safe to do so. In the meantime the integrated configurable auxiliary contact will change state to indicate that the automatic reset did not take place.
Compatible with:
-GW90992 ModBus RS485 interface module.
NOTE: the Autotest function automatically and periodically (every 28 days) tests the RCCB, without interrupting the electric power supply, thus maintaining the performance of the residual current protection over time.
230 V ac power supply, phase-neutral.
RCCB's type B and A[IR] Impulse Resistant presents greater resistance to untimely tripping in comparison to standard residual current circuit breakers. Immunity level 8/20µs: 3000A for IR type, 250A for standard type.
services

Do you need technical assistance?

Contact us to get the answers to your questions: plant, regulatory or product questions.

Find Gewiss

Are you looking for an installer or a sales point?

Find your trusted dealer or installer.

Write to us

Do you need information on Gewiss products or services?