Description Load management relay p-comfort
Model Wire version
Rated voltage (V) 230 ac
No. of modules EN 50022 2
Rated current 32 A
Type relay contact Changeover (potential free contact)
Capacity relay contact 16 A AC1 250 V ac
Standard EN 60669-1, EN 60669-2-1
Rated frequency (Hz) 50
Insulation voltage (Ui) 1000 V
Rated impulse
withstand voltage (Uimp)
1 kV
Section rigid cable Max 6 mm²
Section flexible cable Max 4 mm²
Rigid cable section for contact terminals Max 4 mm²
Flexible cable section for contact terminals Max 2,5 mm²
Operating temperature -5 ÷ +45 °C
Stocking temperature -25 ÷ +70 °C
Absorbed power with In 2 VA
Sound level at 10 cm 85 Db
Measured sizes Active power (absorbed and supplied), active energy (absorbed and supplied)
Resetting of energy count Yes
Acoustic warning threshold exceeded Yes
Adjustament power range 0 ÷ 8 kW (3,8 kW default)
Adjustment of non-priority load contact opening delay time 10 ÷ 120 s (45 s default)
Adjustment of non-priority load contact opening time 10 ÷ 255 s (90 s default)
Electrocod 140
Ware Number 85389099

Product Data Sheet

User guide

Disposal

Technical characteristics - IT

Technical characteristics - DE

Technical characteristics - EN

Technical characteristics - ES

PROJEX

Low voltage system design

Show more

PBT-Q

Low voltage systems and boards

Show more

CENTRAL

Quotation and Thermal test of modular enclosures

Show more

PRICE

Estimation of electrical systems

Show more

ENERGYpro

Boards for building sites, campings-piers and distribution

Show more

CADpro

Advanced design of electrical systems

Show more

CE marking

EQUIPMENT AND NOTES
APPLICATION: The P-Comfort relay can be installed in electrical systems up to 6 kW. In the event of overload due to the simultaneous switching of several electric loads, P-Comfort prevents power supply interruption disconnecting the non-preferential loads wired to the relay inside the device. After a time period, P-Comfort automatically power supplies non-preferential loads again, avoiding service interruptions. P-Comfort allows the measurement and visualisation on the display of the active energy values (supplied and absorbed), and instantaneous active power (supplied and absorbed).
services

Do you need technical assistance?

Contact us to get the answers to your questions: plant, regulatory or product questions.

Find Gewiss

Are you looking for an installer or a sales point?

Find your trusted dealer or installer.

Write to us

Do you need information on Gewiss products or services?