NEW

RESIDUAL CURRENT RELAY WITH SEPARATED TOROID - 230V ac - TYPE B - 3 MODULES

Code: GW96331B
Range: 90 AM Range
Modular accessories
The 90 AM range, in addition to auxiliaries common for the all circuit breakers, comprises many modular accessories for the protection, command, programming, measurement and signalling in electrical systems.

Technical Info

Information
Download
Software
Certificates
Description Residual current relay with separate toroid
Type B
Dimensions 3 modules
Standard EN 60947-2 Annex M
Red LED report Exceeding the threshold IΔn after the delay time Δt
Rated operating voltage (Ue) 230 V ac
Green LED report Device properly powered
Operating voltage range 0,85 x Ue - 1,1 x Ue
Blinking green LED report Exceeding the IΔn pre-alarm threshold
Rated frequency (Hz) 50 Hz / 60 Hz
Local reset Yes
Regulation of IΔn 0,03 - 0,1 - 0,3 - 0,5 - 1 - 3 - 5 - 10 A
Remote Reset Yes
Regulation of delay time Δt 0,1 - 0,2 - 0,3 - 0,4 - 0,5 - 0,75 - 1 - 5 - 10 s
Local test Yes
Insulation class II

Alarm output contact type

Changeover (250 V - 10A - AC1)
Rated operating voltage with reference to the controlled circuit (Un) 400V ac
Fault output contact type Changeover (250 V - 10A - AC1)
Rated insulation voltage with reference to the controlled circuit (Ui) 0,72 kV
Minimum switchable load of output contact 300 mW (5 V / 5 mA)
Rated impulse withstand voltage with reference to the controlled circuit (Uimp) 4 kV (cat. III)
Maximum cable section (rigid/flexible) 2.5 mm²
Rated insulation voltage with reference to the voltage source (Ui) 300V
Tightening torque 0,5 Nm
Rated impulse withstand voltage with reference to the voltage source (Uimp) 4 kV (cat. III)
Working temperature -5°C +40°C (average ≤ 35 °C / 24 h)
Rated short-time withstand current (Icw) 40 kA (0,5 s)
Stocking temperature -25 °C +55 °C (+70 °C < 24 h)
Rated short-time withstand residual current (IΔw) 40 kA (0,5 s)
Humidity 5 % ÷ 90 %
- -
Maximum installation altitude 2.000 m
Ware Number 85364900

Product Data Sheet

User guide

Technical characteristics - IT

Technical characteristics - DE

Technical characteristics - EN

Technical characteristics - ES

CADpro

Advanced design of electrical systems

Show more

ENERGYpro

Boards for building sites, campings-piers and distribution

Show more

PBT-Q

Low voltage systems and boards

Show more

PROJEX

Low voltage system design

Show more

PRICE

Estimation of electrical systems

Show more

CENTRAL

Quotation and Thermal test of modular enclosures

Show more

Conformity declaration

CE marking

EQUIPMENT AND NOTES
CHARACTERISTICS: the tripping (Idn) and delay (dt) thresholds are adjustable:
Idn (A): 0,03 - 0,1 - 0,3 - 0,5 - 1 - 3 - 5 - 10.
dt (s): 0,1 - 0,2 - 0,3 - 0,4 - 0,5 - 0,75 - 1 - 5 - 10.
NOTE: mounting on DIN rail EN 50022. For the operation of the residual current protection, it is necessary to use: the residual current relay, a suitable toroid, and a release for the associated circuit breaker.
services

Do you need technical assistance?

Contact us to get the answers to your questions: plant, regulatory or product questions.

Find Gewiss

Are you looking for an installer or a sales point?

Find your trusted dealer or installer.

Write to us

Do you need information on Gewiss products or services?