COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - 2P CURVE B 16A 10KA TYPE F Idn=0,03A - 2 MODULES

Code: GW95967
Range: 90 RCD Range
Modular circuit breakers for residual current protection
The 90 RCD range meets any ground fault protection requirement for any area of application.
The range comprises MDC compact residual current c.b. with overcurrent protection. (from 6 to 32 A, curves B and C, up to 10 kA and lΔn from 30 and 300 mA type AC, A, A[IR] and A[S] and F) BD and BDHP, add-on residual current devices for circuit breakers MT and MTHP (lΔn from 10 mA to 3 A type AC, A, A[IR], A[S] and A adjustable) IDP residual current circuit breakers (up to 125 A, lΔn from 10 to 500 mA type AC, A, A[IR], A[S], F, B).

Technical Info

Information
Download
Software
Certificates
Description RCCB WITH OVERCURRENT PROTECTION
Code MDC 100
No. of poles 2P
No. modules 2
Rated current 16 A
Rated residual operating current 30 mA
Type F
Curve B
Rated voltage (IEC/EN 61009-1, 61009-2-1) 230/240 V
Energy limiting class 3
Standard IEC/EN 61009-1, IEC/EN 61009-2-1, IEC/EN 62423
Rated frequency (Hz) 50/60 Hz
Breaking capacity IEC/EN 61009-1 230V (Icn) 10000 A
Breaking capacity IEC/EN 61009-1 (Ics) 0.75 x Icn
Breaking capacity IEC/EN 60947-2 230V (Icu) 15 kA
Breaking capacity IEC/EN 60947-2 (Ics) 50% Icu
Insulation voltage (Ui) 500 V
Level of immunity (8/20 μs) 3000 A
Rated impulse withstand voltage (Uimp) 4 kV
Overvoltage category III
Electrical endurance 10.000
Mechanical endurance 20.000
Section rigid cable <=1x35 - <=2x16 - <=1x16+2x10 mm²
Section flexible cable <=1x35 - <=2x16 - <=1x16+2x10 mm²
Double connection YES (only down stream)
Rated tightening torque 2 Nm
Operating temperature -25 +60° C (derating of In with T>30° C)
Stocking temperature -40°C ÷ +70°C
Auxiliaries compatibility Yes
ReStart compatibility Yes
Assembly position Any
Ware Number 85362010

Product Data Sheet

User guide

Depliant - EN

Depliant - IT

Technical characteristics - IT

Technical characteristics - EN

Technical characteristics - DE

Technical characteristics - ES

ENERGYpro

Boards for building sites, campings-piers and distribution

Show more

CENTRAL

Quotation and Thermal test of modular enclosures

Show more

PROJEX

Low voltage system design

Show more

PBT-Q

Low voltage systems and boards

Show more

PRICE

Estimation of electrical systems

Show more

CADpro

Advanced design of electrical systems

Show more

Reach Declaration

Conformity declaration

Display the certificate

CE marking

EQUIPMENT AND NOTES
CARATTERISTICHE: F type presents greater resistance to mains disturbances and atmospheric discharges rn comparison to standard residual current circuit breakers with overcurrent protection. Immunity level 8/20 μs is 3000 A.
services

Do you need technical assistance?

Contact us to get the answers to your questions: plant, regulatory or product questions.

Find Gewiss

Are you looking for an installer or a sales point?

Find your trusted dealer or installer.

Write to us

Do you need information on Gewiss products or services?