RESTART RD - 2 POLES - COUPLED WITH RCCB'S IDP - 25 A TYPE A Idn=0,03 A 230 V - 3 MODULES EN 50022

Code: GWD4817R

Range: 90 ReStart Range
Automatic reclosing devices

In the event the switch trips, the ReStart devices, after checking the system status, restore the power supply thereby ensuring maximum continuity of service in complete safety.
Available for both residual current circuit breakers and residual current circuit breakers with overcurrent protection, the range is characterized by the Autotest functions, with periodic and automatic control of the residual current protection without interrupting the power supply and PRO with extended control of the system.

Technical Info

Information
Download
Software
Certificates
Description Automatic reclosing device
Code ReStart Rd 2P
Coupled with GWD4817
Rated voltage AC 230 V
Rated current 25 A
No. modules 3
Standard EN 50557
Rated frequency (Hz) 50 - 60 Hz
Distribution system TT - TN-S
Rated non-operating resistance between live parts and earth (Rdo) 8kΩ
Insulation voltage (Ui) 500 V
Rated operating resistance between live parts and earth (Rd) 16 kΩ
Rated impulse
withstand voltage (Uimp)
4 kV
Maximum operating frequency 30 oper./h
Overvoltage category III
Mechanical endurance 4000
Dielectric strength test voltage between pole and earth 2500 Vac for 1 minute
Type of residual current protection A
Rated residual operating current 30 mA
Operating temperature -5 +40 °C
Stocking temperature -40 +70 °C
Automatic reclosure for untimely tripping Yes
Earth failure test Yes
Continuous system monitoring No
Number of poles 2P
Electrocod 1414
Ware Number 85362010

Product Data Sheet

User guide

Technical characteristics - IT

Technical characteristics - DE

Technical characteristics - EN

Technical characteristics - ES

CADpro

Advanced design of electrical systems

Show more

CENTRAL

Quotation and Thermal test of modular enclosures

Show more

PROJEX

Low voltage system design

Show more

PBT-Q

Low voltage systems and boards

Show more

ENERGYpro

Boards for building sites, campings-piers and distribution

Show more

PRICE

Estimation of electrical systems

Show more

Conformity declaration

Display the certificate

CE marking

EQUIPMENT AND NOTES
CHARACTERISTICS: after RCCB has tripped, ReStart checks the insulation prior to the automatic reclosure. In the event of a fault (earth leakage), ReStart will not reset the circuit breaker.
NOTE: the ARD must be supplied at 230 Vac phase-neutral.
services

Do you need technical assistance?

Contact us to get the answers to your questions: plant, regulatory or product questions.

Find Gewiss

Are you looking for an installer or a sales point?

Find your trusted dealer or installer.

Write to us

Do you need information on Gewiss products or services?